London Underground Approved Transformers

Transformers for the Railway Industry:

TMC is a long established and approved supplier to the railway industry.  Our design and quality assurance team have worked closely with design, development and manufacturing projects with many major companies, including, London Underground, Network Rail, Invensys Rail, and have over 35 years experience within the industry. 

We are an approved supplier to London Underground for Signalling & Servicing transformers (Vendor Number : 10016182) and are fully Link Up approved. Click here to view our certificate.

Our product portfolio stretches from transformers used for signalling to  transformer/distribution units for use with Servicing in Section 12 locations.

SERVICING TRANSFORMERS

Please view the table and pictures below for a sample of London Underground Approved Servicing Transformers.

 

 

KVA TMC Part No LUL PT No EWT. PT No. CASE DWG No. BRIEF DESCRIPTION: 1-PH 50Hz to LUL spec. CEE 518A LUL Drg.: 2-9569-L20163 Price (NETT EA) WEIGHT (APRX)
10.0  

Similar to T7 But 415V Primary

EWT1215 EW1405 Issue 2 Pri: 380/415/440V Sec 1: 55, 60V Sec 2: 55, 60V Ventilated case floor/wall mounting to IP21 with 2 off 50A DP C type “Crabtree” Polestar MCB’s on front of case.
POA
105 Kg
10.0   Similar to T7 But 415V Primary But Section 12 EWT1227 EW1411 Issue 1 Pri: 380/415/440V Sec 1: 55, 60V Sec 2: 55,60V Non ventilated stainless steel or Galvanised case floor/wall mounting to IP55, with 2 off 50A DP “Crabtree” C50 MCB’s on front of case for Hazardous areas. Section 12
POA
126 Kg
6.0  

617/9610 T6

EWT1220 EW1171 Issue 2

Pri: 220/240/260V Sec 1: 55V Sec 2: 55V Ventilated case floor/wall mounting to IP21 with 2 off 32A DP C type “Crabtree” Polestar MCB’s on front of case.

POA
77 Kg
6.0 TMC-1081 Sim to 617/9610 But Section 12 T6 EWT1148 EW1390 Issue 2 Replaced By: T1058 Rev 1 Pri: 220/240/260V Sec 1: 55V Sec 2: 55V Non ventilated stainless steel case floor/wall mounting to IP55, with 2 off 30A DP “Crabtree” Polestar MCB’s on front of case (for Hazardous areas). Section 12
POA
85 Kg
6.0   617/9607 T6 EWT1222 EW1171 Issue 2 Pri: 220/240/260V Sec 1: 55V Sec 2: 55V Ventilated case floor/wall mounting to IP21 without MCB’s
POA
76 Kg
6.0   Sim to 617/9607 But Section 12 T6 EWT1219 EW1415 Issue 1 (Sim to EW1390) Pri: 220/240/260V Sec 1: 55V Sec 2: 55V Non ventilated stainless steel case floor/wall mounting to IP55, without MCB’s (for Hazardous areas). Section 12
POA
91 Kg
6.0   617/9654

EWT1221

EW1255 Issue C (For UTS Racks only). Pri: 220/240/260V Sec 1: 55V Sec 2: 55V Ventilated case floor mounting to IP21 without MCB’s. Ticket machines only.
POA
76 Kg
2.0

TMC-1103

617/9606 T5 EWT1223 EW1387 Issue 2 Pri: 220/240/260V Sec 1: 55V Sec 2: 55V Non ventilated case floor/wall mounting to IP22 without MCB’s.
POA
41 Kg
2.0   Sim to 617/9606 But Section 12 T5 EWT1197 EW1400 Issue 1 Pri: 220/240/260V Sec 1: 55V Sec 2: 55V Non ventilated stainless steel case floor/wall mounting to IP55, without MCB’s (for Hazardous areas). Section 12
POA
53 Kg
2.0   Sim 617/9606 But with MCB’s T5 EWT1247 EW1387 Issue 2 Pri: 220/240/260V Sec 1: 55V Sec 2: 55V Non ventilated case floor/wall mounting to IP22 with 2 off 10A “Crabtree” Polestar MCB’s.
POA
43 Kg
2.0   817/9600 EWT4075 EW1387 Issue 2 Pri: 220/240/260V Sec 1: 55V Sec 2: 55V Non ventilated case floor/wall mounting to IP22 with 2 off 20A “Reyrolle” Pullcap Fuses. For cash dispensers.
POA
41 Kg
2.0   Sim to 617/9606 With MCB’s Section 12 T5 EWT1228 EW1412 Issue 1 Pri: 220/240/260V Sec 1: 55V Sec 2: 55V Non ventilated stainless steel case floor/wall mounting to IP55. with 2 off 10A “Crabtree” Polestar MCB’s.
POA
55 Kg
0.75   617/9603 T2 EWT1229 EW1181 Issue 2 Pri: 220/240/260V Sec 1: 55V Sec 2: 55V Ventilated case floor/wall mounting to IP21 without MCB’s.
POA
17 Kg
0.75   Sim to 617/9603 But Section 12 T2 EW1288 EW1421 Pri: 220/240/260V Sec 1: 55V Sec 2: 55V Non ventilated stainless steel case floor/wall mounting to IP55, without MCB’s (for Hazardous areas). Section 12
POA
23 Kg
0.20   Sim to 617/9603 But 200VA EWT1573 EW1096 Issue H W2 Pri: 220/240/260V Sec 1: 55V Sec 2: 55V Ventilated case floor/wall mounting to IP21without MCB’s, no knockouts.
POA
7.2 Kg

 

SIGNALLING TRANSFORMERS

TMC hold designs and manufacture over 100 different types of transformers used with Railway signalling.  Please see some examples below

PLEASE CONTACT TMC SALES FOR A FREE ESTIMATE OR FURTHER ASSISTANCE.